8241F
22AWG Stranded RG59 Coaxial Cable
- RG-59/U
- 22 AWG stranded (7x30)
- Bare copper conductor
- Foam polyethylene insulation
- Bare copper braid shield (95% coverage)
- PVC jacket
Specifications | |
Conductor | |
AWG | 22 |
Stranding | 7x30 |
Material | BC - Bare Copper |
Nominal Diameter | 0.03 in |
No. of Coax | 1 |
Insulation | |
Material | PE - Polyethylene (Foam) |
Nominal Diameter | 0.146 in |
Outer Shield Material | |
Type | Braid |
Material | Braid Bare Copper (BC) |
Coverage (%) | 95% |
Outer Jacket Material | |
Material | PVC - Polyvinyl Chloride |
Nominal Diameter | 0.241 in |
Conductor DCR | |
Nominal Conductor DCR | 15 Ohm/1000ft |
Nominal Outer Shield DCR | 2.6 Ohm/1000ft |
Outer Conductor DCR | 2.6 Ohm/1000ft |
Capacitance | |
Nom. Capacitance Conductor to Shield | 17.3 pF/ft |
Inductance | |
Nominal Inductance | 0.09 µH/ft |
Impedance | |
Nominal Characteristic Impedance | 75 Ohm |
Delay | |
Nominal Delay | 1.3 ns/ft |
Nominal Velocity of Propagation (VP) (%) | 78% |
Temperature Range | |
Operating Temp Range | -30°C To +60°C |
Mechanical Characteristics | |
Bulk Cable Weight | 33 lbs/1000ft |
Max. Pull Tension | 65 lbs |
Min Bend Radius/Minor Axis | 2.5 in |
Standards | |
CPR Euroclass | Fca |
RG Type | 59/U Type |
Applicable Environmental and Other Programs | |
Environmental Space | Indoor (Not Riser or Plenum) |
EU Directive 2000/53/EC (ELV) | Yes |
EU Directive 2003/96/EC (BFR) | Yes |
EU Directive 2011/65/EU (ROHS II) | Yes |
EU Directive 2012/19/EU (WEEE) | Yes |
EU Directive 2015/863/EU | Yes |
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
EU CE Mark | No |
EU RoHS Compliance Date (yyyy-mm-dd) | 2004-01-01 |
MII Order #39 (China RoHS) | Yes |
Suitability | |
Suitability - Burial | Yes |
Suitability - Indoor | Yes |
Suitability - Outdoor | Yes |
Plenum/Non-Plenum | |
Plenum (Y/N) | No |
*Product design & specifications are subject to change without notice.